SWMM5 Groundwater Flow Components

Note:  There are three sub flow components in the calculation of the groundwater flow from a SWMM 5 Subcatchment. 

1st Component: Flow = Groundwater Flow Coef. * (LowerDepth – Aquifer Bottom to Node Invert) ^ Groundwater Flow Exponent

2 nd Component: Flow = SurfaceWater Flow Coef. * (Aquifer Bottom to Water Surface – Aquifer Bottom to Node Invert) ^ SurfaceWater Flow Exponent

 3rd Component: Flow = SurfaceWater-Groundwater Flow Coef. * (Aquifer LowerDepth * Aquifer Bottom to Node Invert)

The total flow is the sum of all three components.

InfoSWMM and H2oMAP SWMM Map of the Maximum Surcharge Depth Over Highest Pipe Crown

Note:  You can copy and paste information from the Junction Output Summary to a newly created Junction Information DB Column so that you can use Map Display to visually see the newly saved output variable.

Step 1:  Run the model and then go to the Junction Summary in Report Manager and select all of the nodes in your model.

Step 2:  Copy the Maximum Surcharge Height over Highest Pipe Crown Column

 Step 3:  Make and Insert a New Editable Field in the Junction Information Table by Pasting the information you just copied from the Junction Summary  Output Column.

 Step 4:  Use the Map Display Command and use Existing DB as the Source and the newly created variable Junction_Surcharge_Depth

 

Step 5:  Use the Option Show Label Properties and adjust the Font to show the maximum surcharge depth.