InfoSWMM 2D Report Variables
The Junction Graph variables for 2D Depth, 2D Speed, 2D Froude Number, 2D Unit Flow, 2D Inflow, 2D Volume and 2D Angle for a InfoSWMM 2D simulation for up to 1000 years can be plotted in the Report Manager of InfoSWMM. This is an image of the 2D inflow over a 10 year period (A), all seven graph variables (B) for the mesh triangle associated with the 1D node (C). The 2D inflow is + for flow out of the node to a mesh triangle and – for flow from the mesh triangle to the 1D junction.