Time Base is T + T*K from the Time(T) and Storage (K) values

Note:  Each of the RDII UH’s has a base time for the convolution of the RDII from each UH.  The Time Base is T + T*K from the Time(T) and Storage (K) values  used in the RTK data.  In this particular case:

 ·         The Fast UH has a time base of 22 hours,

·         The Medium UH has a time base of 430 hours, and

·         The Slow UH has a time base of 4212 hours.

 If this is altered as in the  bottom image you can see the difference in the total  RDII I&I Flow

 ·         The Fast UH has a time base of 22 hours,

·         The Medium UH has a time base of 36 hours, and

·         The Slow UH has a time base of 52 hours.